A working glossary for owners, consultants and integrators — the terms that show up in an IBMS scope, a point schedule or a commissioning meeting.

Plain definitions, not acronym soup.

Fundamentals

06
IBMS
Intelligent Building Management System: the integration layer that unifies building subsystems into one operating picture.
BMS
Building Management System: the plant-level system that controls HVAC, lighting and other building services.
BAS
Building Automation System: the control system for mechanical and electrical services, often used interchangeably with BMS.
Point schedule
The list that defines every point, its address, range, alarm limits and naming.
Interlock
A rule that makes one system respond to an event in another, such as access opening a room and triggering lighting and HVAC.
Trend log
A time-stamped history of a point or group of points, used for analysis and performance review.

Protocols

08
BACnet
An open building-automation protocol used by plant, AHUs and BMS; BACnet/IP runs over Ethernet.
Modbus
A simple serial or TCP protocol widely used by meters, inverters, sensors and PLCs.
KNX
A building-control standard for lighting, shading and room control, common in Europe.
DALI
A digital lighting protocol for dimming and addressing individual luminaires.
DMX
A lighting-control protocol used for theatrical, architectural and scene lighting.
1-Wire
A low-speed bus for sensors such as temperature probes.
EnOcean
A wireless, energy-harvesting protocol for sensors and switches.
REST API
A web interface for exchanging data with a system, typically over HTTPS.

Systems & roles

05
HVAC
Heating, ventilation and air conditioning: the plant and distribution that control temperature, humidity and fresh air.
RCU
Room Control Unit: the in-room controller that coordinates lighting, HVAC, shading and service requests in a hotel guest room.
PMS
Property Management System: the hotel front-office system that manages reservations, check-in and check-out.
OCPP
Open Charge Point Protocol: the standard for communicating with EV charging stations.
Access control
The system that manages who can enter which door, when, and records the event.

Performance & health

07
Setpoint
The target value a control loop maintains, such as 22 °C or 600 ppm CO2.
Alarm rationalisation
The process of reducing, ranking and grouping alarms so operators can act on what matters.
CO2
Carbon dioxide concentration, a proxy for ventilation and occupancy; high-performance targets are below 600 ppm.
PM2.5
Fine particulate matter; high-performance targets are below 15 ug/m3.
TVOC
Total volatile organic compounds; high-performance targets are below 0.4 mg/m3.
Demand-controlled ventilation
A control strategy that modulates fresh air based on CO2, occupancy or air quality.
Baseline
The reference consumption or performance against which savings and operation are measured.